Customization: | Available |
---|---|
Warranty: | 18 Months |
Kind: | Digital Oscilloscope |
Still deciding? Get samples of US$ 158/set
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | SA62D15 | SA62D10 | SA62C15 | SA62C10 | |||||
Overview | |||||||||
Oscilloscope | 2 analog channels | ||||||||
Waveform Generator | Standard | Standard | N/A | N/A | |||||
Serial Protocol Analysis | UART, LIN, CAN, IIC, SPI | ||||||||
Integrated Digital Voltmeter (DVM) | Standard | ||||||||
External Trigger | 1 | ||||||||
OSCILLOSCOPE | |||||||||
Input | |||||||||
Analog Channel | 2 | ||||||||
Input Coupling | AC, DC, GND | ||||||||
Input Impedance/Capacitance | 1MΩ±1% / 20pF±3pF (DC coupling) | ||||||||
Standard Probe Attenuation | 1X, 10X | ||||||||
Supported Probe Attenuation Factor | 1X, 10X, 100X, 1000X | ||||||||
Overvoltage Category | CATII 300V | ||||||||
Maximum Input Voltage | 300VRMS (10×) | ||||||||
Vertical | |||||||||
Bandwidth | 150MHz | 100MHz | 150MHz | 100MHz | |||||
Rise Time at BNC (typical) | ≤ 2.4ns | ≤3.5ns | ≤ 2.4ns | ≤ 3.5ns | |||||
Vertical Resolution | 8-bit resolution, all channels sampled simultaneously | ||||||||
Input Sensitivity Range | 2mV/div to 10V/div | ||||||||
Offset Range | 2mV/div to 200mV/div, ±1V 500mV/div to 10V/div, ±50V |
||||||||
Bandwidth Limits | 20MHz (selectable) | ||||||||
Invert Signal | Selectable | ||||||||
Low Frequency Response (-3db) | ≤10Hz at BNC | ||||||||
DC Gain Accuracy | ±3% full scale for Normal or Average acquisition mode, 10V/div to 10mV/div; ±4% full scale for Normal or Average acquisition mode, 5mV/div to 2mV/div |
||||||||
DC Offset Accuracy | ±0.1div ± 2mV ± 1% offset setting | ||||||||
Skew | 2ns | ||||||||
Note: when using a 1X probe, bandwidth reduce to 6MHz | |||||||||
Horizontal | |||||||||
Time Base Range | 2ns/div to 100s/div (in 1-2-5 sequence) | ||||||||
Sample Rate and Delay Time Accuracy | ±50ppm | ||||||||
Delta Time Measurement Accuracy (Full Bandwidth) | Single-shot, Normal mode: ± (1 sample interval +100ppm × reading + 0.6ns) >16 averages: ± (1 sample interval + 100ppm × reading + 0.4ns) Sample interval = s/div ÷ 200 |
||||||||
Acquisition | |||||||||
Max. Sample Rate | 1GSa/s for half channels 500MSa/s for all channels |
||||||||
Memory Depth | Max. 8M for half channels Max. 4M for all channels |
||||||||
Waveform Interpolation | (sin x)/x | ||||||||
Waveform Update Rate (Typical) | Up to 2,000 waveform per second each channel (Normal acquisition mode, no measurement) | ||||||||
Acquisition Mode | Normal, Peak Detect, Average, HR (High Resolution) | ||||||||
Time Mode | YT (default mode), XY (volts vs. volts display), Roll (displays the waveform moving across the screen from right to left) | ||||||||
Autoset | Finds and displays all active channels and external trigger. And automatically configures the best display of the input signals on these channels. | ||||||||
Single Sequence | Acquisition Mode | Acquisition Stop Time | |||||||
Normal, Peak Detect | Upon single acquisition on all channels simultaneously | ||||||||
Average | After N acquisitions on all channels simultaneously, N can be set to 4, 8, 16, 32, 64 or 128 | ||||||||
Trigger | |||||||||
Trigger Modes | Auto, Normal, Force (front panel key that forces a trigger) | ||||||||
Trigger Source | CH1, CH2, EXT, AC Line | ||||||||
Trigger Holdoff Range | 20ns to 10s | ||||||||
Trigger Level Range | Internal: ±5 divisions from center screen External: 3.3V (CMOS) |
||||||||
Trigger Level Accuracy ( typical) | Internal: 0.2div × volts/div within ± 4 divisions from center screen | ||||||||
Trigger Sensitivity | ±0.2 div | ||||||||
Set Level to 50% (typical) | Operates with input signals ≥50Hz | ||||||||
Trigger Types | Edge, Pulse width, Video, Slope, Over time, Window, Pattern, Interval, Under Amp | ||||||||
Edge | Trigger on a rising, falling, or either edge of any source | ||||||||
Pulse Width | Trigger on a pulse of a selected channel with a time duration that is 'less than a value,' 'greater than a value' , 'equal to a value' or 'not equal to a value' Range: 8ns to 10s |
||||||||
Video | Trigger on scan lines or individual lines; odd/even or all fields from the composite video; or broadcast standards (PAL and NTSC) | ||||||||
Slope | Trigger on rising or falling slope of the specified time. This trigger mode is applicable to ramp and triangle waveforms. Time setting range: 8ns to 10s |
||||||||
Overtime | Trigger when the time interval is greater than the pre-set timeout value. | ||||||||
Window | Trigger when the input signal passes through the high trigger level or the low trigger level. | ||||||||
Pattern | Trigger when a specified pattern on any combination inputs is entered. | ||||||||
Interval | Trigger on rising or falling edge when the time between the edges is within the specified time. You can use this trigger to find missing or mistimed edges, or changes in signal frequency. | ||||||||
Under Amp | Trigger pulses that pass through one trigger level but fail to pass through another trigger level. | ||||||||
UART | Trigger on start frame position, stop frame position, specified data, parity error or communication error. | ||||||||
LIN | Trigger on LIN (Local Interconnect Network) interval filed, sync field, ID field, sync code error, or specified identifier, frame ID and data. | ||||||||
CAN | Trigger on the start of frame bit, remote frame ID, data frame ID, remote or data frame ID, data frame ID and data, error frame, all errors, acknowledge error, and overload frame of the CAN (controller area network) signal. | ||||||||
SPI | Trigger on SPI (Serial Peripheral Interface) data pattern during a specific framing period. | ||||||||
IIC | Trigger at a start/stop bit or specified address and/or data values. Also, trigger on missing acknowledge, restart. | ||||||||
Measurements | |||||||||
Cursors | Voltage difference between cursors: △V Time difference between cursors: △T Reciprocal of △T in Hertz (1/ΔT) |
||||||||
Auto Measurements | Voltage: Peak to peak, Average, Maximum, Minimum, Vtop, Vmid, Vbase, Vamp, RMS, R-Overshoot, F-Preshoot, Preiod RMS, Preiod Average, F-Overshoot, R-Preshoot Time: Frequency, Period, Rise time, Fall Time, + Width, - Width, +Duty, -Duty, BWidth, FRR, FFF, FRF, FFR, LRR, LRF, LFR, LFF |
||||||||
Waveform Math | |||||||||
Arithmetic | +, -, x , ÷, FFT | ||||||||
FFT | Window types: Hanning, Hamming, Flattop, Rectangular, Bartlett, Blackman Sample point: 1024 |
||||||||
DVM (DIGITAL VOLTMETER) | |||||||||
Functions | DC RMS, AC RMS, DC | ||||||||
Data Source | CH1, CH2 | ||||||||
Resolution | 3 digits | ||||||||
FREQUENCY COUNTER | |||||||||
Functions | Frequency | ||||||||
Data Source | CH1, CH2 | ||||||||
Resolution | 5 digits | ||||||||
BUILT-IN ARBITRARY/FUNCTION GENERATOR (only available for SA62D15 and SA62D10) | |||||||||
WaveGen Out | 1CH Front-panel BNC connector | ||||||||
Waveforms | Sine, square, ramp, exponential rise (EXP), noise, DC, arbitrary. | ||||||||
Modulation | Modulation Type | AM | Modulation Frequency: 1Hz to 75MHz Depth: 0 to 120% |
||||||
FM | Modulation Frequency: 1Hz to 75MHz Deviation: 0.1Hz to carrier frequency |
||||||||
Carrier Wave | Sine, ramp | ||||||||
Modulation | Sine, square, ramp | ||||||||
Burst | Types | N Cycle, Infinite | |||||||
Count | 1 to 1024 | ||||||||
Trigger Source | Manual | ||||||||
Frequency | Sine: 0.1Hz to 25MHz Square: 0.1Hz to 10MHz Ramp: 0.1Hz to 1MHz Exponential Rise: 0.1Hz to 5MHz Arbitrary: 1uHz~75MHz |
||||||||
Noise Bandwidth | >25MHz | ||||||||
Output Impedance | 50 Ω + 1% high impedance | ||||||||
Amplitude | 5mV to 3.5Vpp (50Ω) 10mV to 7Vpp(High impedance) |
||||||||
DAC | 2K~200MHz adjustable | ||||||||
Frequency Resolution | 1uHz | ||||||||
Waveform Depth | 4KSa | ||||||||
Vertical Resolution | 12 bit | ||||||||
Frequency Accuracy | 100ppm (frequency <10KHz) 50ppm (frequency >10KHz) |
||||||||
Amplitude Accuracy | ±3dB | ||||||||
Display | |||||||||
Display Type | 7 inch TFT (diagonal liquid crystal) | ||||||||
Display Resolution | 800 horizontal by 480 vertical pixels | ||||||||
Connectivity | |||||||||
Standard Ports | USB 2.0 (host and device) | ||||||||
Probe Compensator Output | |||||||||
Output Voltage ( typical) | About 5V into ≥1MΩ load | ||||||||
Frequency (typical) | 1kHz ± 1% | ||||||||
Power Supply | |||||||||
Supply Voltage | 100-120VACRMS(±10%), 45Hz to 440Hz 120-240VACRMS(±10%), 45Hz to 66Hz |
||||||||
Power Consumption | <15W | ||||||||
Fuse | T2A 250VAC 4x8 | ||||||||
Environmental | |||||||||
Temperature | Operating: 32ºF to 122ºF (0ºC to 50ºC); Storage: -40ºF to 159.8ºF (-40ºC to +71ºC) |
||||||||
Cooling Method | Convection | ||||||||
Humidity | +104ºF or below (+40ºC or below): ≤90% relative humidity; 106ºF to 122ºF (+41ºC to 50ºC): ≤60% relative humidity |
||||||||
Altitude | Operating: Below 3,000m (10,000 feet) | ||||||||
Mechanical | |||||||||
Dimension | 318 x 110 x 150mm (L x W x H) | ||||||||
Weight | 1.90KG |